Absolute Encoder Values Jump Strangely? Check Gray Versus Binary
- PLC Play Ground
- 0
- Posted on
An SSI encoder can communicate reliably while its position is decoded incorrectly. Confirm the encoding before blaming noise or mechanics.
Original three-bit example; use the exact encoder frame specification.
What is happening?
Gray and binary coding assign different bit patterns to positions. Frame length, status bits, single-turn and multi-turn fields also affect decoding. A plausible value at one position does not prove the complete format is correct.
Check these five things
-
Read the encoder output-code specification.
-
Check receiver Gray-to-binary conversion settings.
-
Confirm frame length and data-field placement.
-
Separate status bits from position bits.
-
Compare a sequence of known positions in a test setup.
Worked example
In a three-bit teaching example, binary position 3 is 011 while its reflected Gray code is 010. Treating the Gray pattern as ordinary binary produces 2. Multiple positions are needed to expose the resulting nonlinear interpretation.
Quick diagnostic reference
| Setting | Check |
|---|---|
| Coding | Gray or binary |
| Frame width | Total transmitted bits |
| Field layout | Position versus status |
The mistake to avoid
A simple scale factor cannot correct a coding mismatch across the entire range. Fix the documented decoding arrangement first.
How to verify the fix
Verify monotonic movement, rollover, multi-turn behavior where applicable, and diagnostic bits before enabling dependent motion functions.
Field-work boundary: These are educational diagnostic guides. Use the exact equipment manuals and approved site procedures. Electrical testing and machinery changes belong to qualified, authorized personnel; control hazardous energy and validate affected functions before release.